SHOP FOR
http://base-store.storehippo.com/
# 2514/U, 7th 'A' Main Road, Opp. to BBMP Swimming Pool, Hampinagar, Vijayanagar 2nd Stage. 560104 Bangalore IN
Tenettech E-Store
# 2514/U, 7th 'A' Main Road, Opp. to BBMP Swimming Pool, Hampinagar, Vijayanagar 2nd Stage. Bangalore, IN
+918023404924 https://cdn1.storehippo.com/s/59c9e4669bd3e7c70c5f5e6c/ms.settings/5256837ccc4abf1d39000001/webp/59dafe26aef6e1d20402c4c3-480x480.png" info@tenettech.com
5abb810f7d9062c86e292bd1 HYDROGEN click https://cdn1.storehippo.com/s/59c9e4669bd3e7c70c5f5e6c/ms.products/5abb810f7d9062c86e292bd1/images/5abb810f7d9062c86e292bd2/5abb7f9a500f11022efc7845/webp/5abb7f9a500f11022efc7845.jpg

Description

Hydrogen click carries an MQ-8 sensor for hydrogen (H2). The gas sensing layer on the sensor unit is made of tin dioxide (SnO2), which has lower conductivity in clean air. The conductivity increases as the levels of hydrogen rise. The detection range of the sensor is 100-10000ppm of hydrogen. To calibrate the sensor for the environment you’ll be using it in, Hydrogen click has a small potentiometer that allows you to adjust the load resistance of the sensor circuit. For precise calibration the sensor needs to preheat (once powered up, it takes over 24h to reach the right temperature). Hydrogen click communicates with the target board through AN (OUT) mikroBUS™ line. It’s designed to use a 5V power supply only.
 

Specification

TypeGas
ApplicationsHydrogen detection, gas leakage
On-board modulesMQ-8 sensor for hydrogen (H2)
Key FeaturesPotentiometer for calibration
Key BenefitsThe gas sensing layer on the sensor unit is made of tin dioxide (SnO2), which has lower conductivity in clean air
InterfaceAnalog
Input Voltage3.3V or 5V
CompatibilitymikroBUS
Click board sizeM (42.9 x 25.4 mm)

    TT-MK- MIKROE-1629
    in stockINR 1522.5
    MIKROELECTRONICA
    1 1
    XYZ Blog title
    ABC Blog title here
    HYDROGEN click

    Description of product

    Description

    Hydrogen click carries an MQ-8 sensor for hydrogen (H2). The gas sensing layer on the sensor unit is made of tin dioxide (SnO2), which has lower conductivity in clean air. The conductivity increases as the levels of hydrogen rise. The detection range of the sensor is 100-10000ppm of hydrogen. To calibrate the sensor for the environment you’ll be using it in, Hydrogen click has a small potentiometer that allows you to adjust the load resistance of the sensor circuit. For precise calibration the sensor needs to preheat (once powered up, it takes over 24h to reach the right temperature). Hydrogen click communicates with the target board through AN (OUT) mikroBUS™ line. It’s designed to use a 5V power supply only.
     

    Specification

    TypeGas
    ApplicationsHydrogen detection, gas leakage
    On-board modulesMQ-8 sensor for hydrogen (H2)
    Key FeaturesPotentiometer for calibration
    Key BenefitsThe gas sensing layer on the sensor unit is made of tin dioxide (SnO2), which has lower conductivity in clean air
    InterfaceAnalog
    Input Voltage3.3V or 5V
    CompatibilitymikroBUS
    Click board sizeM (42.9 x 25.4 mm)